The assembly is composed of the fire door frame fire exit hardware door closers hinges locks door bolts and other door components that when combined provide varying degrees of fire protection that is contingent on the door fire rating e g.
Fire door inspection checklist pdf. We are certified to perform detailed 13 points fire doors inspection. Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard. The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing. In addition to all of the components of a fire door assembly.
Open the door and take a look at the hinges. All exit doors should readily open from the inside without the use of a key or special knowledge or effort. Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify. Still a checkmate fire gap gauge take a look at the edges of the door and frame.
View the vision panel and glass from both sides of the door. Fire doors basic guidance checklist introduction fire doors and all passive fire protection products play a unique role in fire. Fire hydrants should be visible and accessible. Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify.
45 minutes 90 minutes. The frequency of each inspection should be determined by assessing among other things the amount of use the door is subjected to the criticality of the. Our fire smoke door experts will provide a thorough inspection of all the doors in the building to ensure they are safe and complying with the nfpa code and prepare a detailed report on the condition and function of the fire door on your facilities. Means of egress all exit doors should be visible accessible and fully functional.
For best results use a checkmate fire gap gauge or use a 1 coin to give a feel for scale this is about 3mm thick. All required fire doors must be self closing and latch in the closed position. Fire door inspection checklist. Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
Open the door about halfway let go and see. To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist.