Exit Door Hardware Requirements
An opening into an exit must be protected by a self closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system.
Exit door hardware requirements. If balanced door s are used and panic hardware is required the panic hardware shall be of the. Fire doors must only be fitted with door hardware fire rated in accordance with. Code publications define panic hardware as a door latching assembly incorporating a device that releases the latch upon the application of a force. The exception being locks in childcare facilities which may be 1500mm 1650mm high as necessary.
And in addition lit by a reliable light source. Each door in a means of egress from an occupa ncy of group a or e having an occupant load of 100 or more and any occupancy of group h 1 h 2 h 3 or h 5 shall not be provi ded with a latch or lock unless it is panic hardware or fire exit hardware. The use of panic hardware and or fire exit hardware is required by the international building code ibc and nfpa 101 the life safety code depending on which code and which edition of the code is being referenced. Door lock heights on exit doors fire doors path of travel doors and disabled access doors now have a standardised lock height of 900mm 1100mm.
Panic hardware also known as an exit device or fire exit hardware when used on fire doors is designed to provide fast and easy egress to allow building occupants to exit safely in an emergency. Purpose all exit doors shall be easily opened from the interior without the use of a key combination or any special knowledge or effort. Sometimes panic hardware is called fire exit hardware or they may be referred to as egress doors. Nfpa emergency exit door requirements for marking.
The ibc 2006 and 2009 editions requires panic hardware and or fire exit hardware on egress doors with an occupant load of 50 people or more in the following. Means of egress exit hardware requirements town of brighton office of the fire marshal october 2018. All exit paths must have a clearly recognizable exit sign. Each fire door including its frame and hardware must be listed or approved by a nationally recognized testing laboratory.
Subsequently place these exit signs only on emergency exit doors and doors leading to an exit. Panic hardware cannot be used on a fire door because of the danger of trapping people inside during a fire. When panic hardware is used on fire doors it must be fire exit hardware that has been tested per ul 10c positive pressure fire tests of door assemblies or another fire test standard and the.