Dryer Vent Through Roof Code
Doing so would fill your attic with warm moist air that could rot the framing.
Dryer vent through roof code. Flexible duct shall not be concealed within the construction. Considering that back pressure higher than 6 wci is generally recognized as inefficient you can see that venting through the roof with non dryer specific vents is immediately problematic. Dryer vents should always be vented through the side of the house and not vented through the roof and ideally the exit should be fairly close to the ground. When bath fans and clothes dryers vent through the roof they melt a bunch of snow.
Clothes dryers should be vented through the side of the house preferably within reach from the ground. The less back pressure is created by the roof vent the more efficiently the system performs. Dryer venting cannot be combined with other systems such as chimneys or exhaust vents. If you have to install bends you should reduce this limit by 5 feet for every 90 degree bend and 2.
The plumbing stacks are used to vent sewer or waste water odors and allow for proper gravity flow. Exhaust ducts shall have a smooth interior finish and shall be constructed of metal a minimum 0 016 inch 0 4 mm thick. Check the local codes and dryer manufacturers recommendations for specifics in your area. Exhaust ducts for domestic clothes dryers shall conform to the requirements of sections 504 6 1 through 504 6 7.
When we bought our condo the home inspector said we might have trouble with the dryer vent and he sure was right. The roof area of a house is used to vent many of the homes mechanical systems. 504 6 1 material and size. Difficulty cleaning dryer vent.
I think the roof is a stupid spot to terminate clothes dryer vents because it s difficult to clean and it s a major contributor to ice dams. The laundry is located in the middle of our home in a hall closet. A proper hood or a roof cap equipped with a backdraft damper must be at the termination of dryer venting. The international residential code allows you to run a dryer vent through the attic but you can t terminate it there.
Keeping a clean dryer vent is much easier when you can safely reach the exit. The maximum length of a 4 inch 102 mm diameter exhaust vent shall not exceed 35 feet 7620 mm from the dryer location to wall or roof termination and shall terminate with a full opening exhaust hood. Bathroom and cooking area fans also vent to the roof generally through a gooseneck style vent that exhibits a damper and grill.